Canned motor pumps with explosion protection for potentially explosive atmospheres
Finding the right canned motor pump
Standard applications
Standard application, single-stage
Flow rate [Q]
max. 1600 m³/h
Head [H]
max. 240 m
Operating temperature [t]
–120 °C to +120 °C
Pressure rating
PN 16 to PN 50
Standard application, multi-stage
Flow rate [Q]
max. 350 m³/h
Head [H]
max. 1200 m³/h
Operating temperature [t]
–120 °C to +120 °C
Pressure rating
PN 16 to PN 100
Variants tailored to specific applications and areas of use
Hot applications, single-stage
Flow rate [Q]
max. 1600 m³/h
Head [H]
max. 240 m³/h
Operating temperature [t]
max. +425 °C
Pressure rating
PN 16 to PN 50



Type CN and CNF
Design / Version
With hot-winding in insulation class R (max. 220°C winding temperature) or insulation class C (max. 400°C winding temperature)


Hot applications, multi-stage
Flow rate [Q]
max. 350 m³/h
Head [H]
max. 1200 m
Operating temperature [t]
max. +400 °C
Pressure rating
PN 16 to PN 100


Type CAM
Design / Version
With hot-winding, insulation class R (max. 220 °C winding temperature) and insulation class C (max. 400 °C winding temperature)
Variants tailored to specific applications and areas of use
High-pressure applications
Flow rate [Q]
max. 1600 m³/h
Head [H]
max. 1200 m
Operating temperature [t]
–120 °C to +360 °C
Pressure rating
max. PN 1200


Variants tailored to specific applications and areas of use
Applications for low viscosities
Flow rate [Q]
max. 1600 m³/h
Head [H]
max. 2300 m
Operating temperature [t]
–120 °C to +360 °C
Pressure rating
PN 16 to PN 150


Variants tailored to specific applications and areas of use
Integrated into the tank farm and/or low NPSHa
Flow rate [Q]
max. 1600 m³/h
Head [H]
max. 1200 m
Operating temperature [t]
–120 °C to +250 °C
Pressure rating
PN 16 to PN 100
Modularly configurable canned motor pumps
CN and CNF type canned motor pumps
Flow rate [Q]
max. 130 m³/h
Head [H]
max. 145 m
Operating temperature [t]
–40 °C to +120 °C
Pressure rating
PN 16 / PN 25
Engine power
max. 48 kW

Type CN
Type / Design
Single-stage standard chemical pump in accordance with EN 22858 / ISO 2858 with canned motor drive
The CN series is the standard version of HERMETIC canned motor pumps. It is suitable for pumping common liquids with a sufficient margin above the vapour pressure (non-boiling media).

Type CNF
Type / Design
Single-stage standard chemical pump in accordance with EN 22858 / ISO 2858 with canned motor drive
The CNF series is designed for liquefied gases, boiling media and condensates. With an integrated auxiliary impeller and internal liquid recirculation, it is suitable for pumping liquids at pressures close to their vapour pressure.
Pump design
With our expert tool, you can quickly find the right pump solution for your application. Based on your process data, you will receive an initial shortlist of suitable series and models.
CAM-type canned motor pump
Flow rate [Q]
max. 40 m³/h
Head [H]
max. 295 m
Operating temperature [t]
–40 °C to +120 °C
Pressure rating
PN 40
Engine power
max. 48 kW

Pump design
With our expert tool, you can quickly find the right pump solution for your application. Based on your process data, you will receive an initial shortlist of suitable series and models.
Get in touch with our team
Are you looking for the right pump for your process requirements, or do you need help with the design? Please contact our team of experts.